Fuzhou Aladdin Ronghai Technology

4

EV Charging Stations

previous arrow
next arrow
0 + Years

Industry Experience

0 +

Registered Patents

0 Million +

Battery Test Cycles

0 +

Safety Protection
Protocols

AC 7 kW EV Charger

Output Voltage
AC 230 V ±10%
Rated Power
7 kW
Charging Modes
Plug & Charge / Card Authorization
Protection Functions
Short-circuit, surge, earth leakage, overvoltage, overcurrent,
undervoltage, overtemperature, emergency stop, rainproof
Communication Protocol
OCPP 1.6
Charging Connector
Type 2
Rated Current
32 A
Residual Current Protection
Internal / External RCD Protection
Operating Temperature
−30 °C ~ +50 °C
Protection Level
IP55
Mounting Type
Wall-mounted / Pole-mounted
Certificates
CE

AC 11 kW EV Charger

Output Voltage
AC 400 V ±20%
Rated Power
11 kW
Charging Modes
Plug & Charge / Card Authorization
Protection Functions
Short-circuit, surge, earth leakage, overvoltage, overcurrent,
undervoltage, overtemperature, emergency stop, rainproof
Communication Protocol
OCPP 1.6
Charging Connector
Type 2
Rated Current
16 A
Residual Current Protection
Internal / External RCD Protection
Operating Temperature
−30 °C ~ +50 °C
Protection Level
IP55
Mounting Type
Wall-mounted / Pole-mounted
Certificates
CE

AC 22 kW EV Charger

Output Voltage
AC 400 V ±20%
Rated Power
22 kW
Charging Modes
Plug & Charge / Card Authorization
Protection Functions
Short-circuit, surge, earth leakage, overvoltage, overcurrent,
undervoltage, overtemperature, emergency stop, rainproof
Communication Protocol
OCPP 1.6
Charging Connector
Type 2
Rated Current
32 A
Residual Current Protection
Internal / External RCD Protection
Operating Temperature
−30 °C ~ +50 °C
Protection Level
IP55
Mounting Type
Wall-mounted / Pole-mounted
Certificates
CE
Maximum Power
120 kW
Charging Gun
Dual gun
Output Voltage
DC 200 – 1000 V
Maximum Current
200 A (CCS), 125 A (CHAdeMO)
Operating Temperature
−20 °C ~ +70 °C
Operating Mode
Automatic, time-based, quantity-based, energy-based, SOC-based
Protection Features
• Overcurrent, short circuit, overvoltage
• Undervoltage, reverse polarity
• Overtemperature protection
Protection Level
IP55 / IK10
Mounting Type
Floor-mounted

DC 120 kW Ultra-Fast Charger

Maximum Power
150 kW
Charging Gun
Dual gun
Output Voltage
DC 200 – 1000 V
Maximum Current
200 A / CCS (optional 350 A), 125 A / CHAdeMO
Operating Temperature
−20 °C ~ +70 °C
Operating Mode
Automatic, time-based, quantity-based, energy-based, SOC-based
Protection Features
• Overcurrent, short circuit, overvoltage
• Undervoltage, reverse polarity
• Overtemperature protection
Protection Level
IP55 / IK10
Mounting Type
Floor-mounted

DC 150 kW Ultra-Fast Charger

Maximum Power
180 kW
Charging Gun
Dual gun
Output Voltage
DC 200 – 1000 V
Maximum Current
200 A / CCS (optional 350 A), 125 A / CHAdeMO
Operating Temperature
−20 °C ~ +70 °C
Operating Mode
Automatic, time-based, quantity-based, energy-based, SOC-based
Protection Features
• Overcurrent, short circuit, overvoltage
• Undervoltage, reverse polarity
• Overtemperature protection
Protection Level
IP55 / IK10
Mounting Type
Floor-mounted

DC 180 kW Ultra-Fast Charger

360 kW Intelligent Flexible Charging Array

Rated Power
360 kW
Charging Gun Configuration
≤ 12 Units
Output Voltage
200–1000 V
Output Current
0–250 A
System Efficiency
≥ 96%
Protection Level (IP)
IP55
Activation Methods
Mobile payment and card authentication (optional)
Communication Interfaces
Ethernet and 4G
Protection Functions
Overvoltage / Undervoltage / Overcurrent / Overload / Short circuit / Reverse connection / Communication fault protection

480 kW Intelligent Flexible Charging Array

Rated Power
480 kW
Charging Gun Configuration
≤ 12 Units
Output Voltage
200–1000 V
Output Current
0–250 A
System Efficiency
≥ 96%
Protection Level (IP)
IP55
Activation Methods
Mobile payment and card authentication (optional)
Communication Interfaces
Ethernet and 4G
Protection Functions
Overvoltage / Undervoltage / Overcurrent / Overload / Short circuit / Reverse connection / Communication fault protection

720 kW Intelligent Flexible Charging Array

Rated Power
720 kW
Charging Gun Configuration
≤ 12 Units
Output Voltage
200–1000 V
Output Current
0–600 A
System Efficiency
≥ 96%
Protection Level (IP)
IP55
Activation Methods
Mobile payment and card authentication (optional)
Communication Interfaces
Ethernet and 4G
Protection Functions
Overvoltage / Undervoltage / Overcurrent / Overload / Short circuit / Reverse connection / Communication fault protection

1.2 MW Intelligent Flexible Charging Array

Rated Power
1200 kW
Charging Gun Configuration
≤ 24 Units
Output Voltage
200–1000 V
Output Current
0–600 A
System Efficiency
≥ 96%
Protection Level (IP)
IP55
Activation Methods
Mobile payment and card authentication (optional)
Communication Interfaces
Ethernet and 4G
Protection Functions
Overvoltage / Undervoltage / Overcurrent / Overload / Short circuit / Reverse connection / Communication fault protection

1.4 MW Intelligent Flexible Charging Array

Rated Power
1400 kW
Charging Gun Configuration
≤ 24 Units
Output Voltage
200–1000 V
Output Current
0–600 A
System Efficiency
≥ 96%
Protection Level (IP)
IP55
Activation Methods
Mobile payment and card authentication (optional)
Communication Interfaces
Ethernet and 4G
Protection Functions
Overvoltage / Undervoltage / Overcurrent / Overload / Short circuit / Reverse connection / Communication fault protection

Merkezi Sıvı Soğutmalı Süper Hızlı Şarj Sistemi

Input Voltage
400 VAC -15% / +10%
Input Power
125 kW
Charging Voltage
200 – 1000 V
Charging Current (Per Channel)
0 – 250 A
Charging Channels
2 / 4 / 6
Charging Power (Per Channel)
90 – 180 kW
Protection Level
IP54
Cooling Method
Liquid-cooled
PV Control Unit (Optional)
45 kW / 90 kW
Energy Storage Battery (Standard)
233 kWh

BESS Supercharging Station

BESS is an intelligent station solution that integrates solar energy (PV), energy storage (ESS), and ultra-fast EV charging within a single hub.

 

  • Integrates: PV (solar), ESS (battery), and ultra-fast charging.

  • Balances: Relieves the transformer during peak hours by supplying energy from storage (peak shaving).

  • Saves: Stores energy during off-peak hours to reduce costs (valley filling).

  • Expands: Helps increase capacity without the need for additional transformers.

  • Smart: Enables full system monitoring and management from a single platform.

EV Safety Operation Inspection Testing System

The EV Safety Operation Inspection and Testing System utilizes advanced detection technologies and intelligent analytics to provide comprehensive evaluations of battery performance and safety.

Portable Battery Cell Balancer

Application Area
Research / Industry / After-Sales
Model
JAT-JTFLCT-300100PT-E002
Charge Voltage
0V ~ 300V
Discharge Voltage
0V ~ 300V
Voltage Accuracy
±0.02% F.S
Current Accuracy
±0.02% F.S
Current Range
0 ~ 100A
Power Accuracy
0.1% F.S
Maximum Power
20 kW
Current Rise Time
5 ms
Switching Time
10 ms
Simulation Time
20 ms
Minimum Sampling Time
10 ms
Number of Channels
1 CH
Input Voltage
Automatic adaptation to global 3-phase grids: 3×208V~3×440V ±10%, 50/60 Hz ±5%
Certificates
CE
Application Area
Research / Industry / After-Sales
Model
JAT-JTFLCT-300100PT-E002
Charge Voltage
0V ~ 300V
Discharge Voltage
0V ~ 300V
Voltage Accuracy
±0.02% F.S
Current Accuracy
±0.02% F.S
Current Range
0 ~ 100A
Power Accuracy
0.1% F.S
Maximum Power
20 kW
Current Rise Time
5 ms
Switching Time
10 ms
Simulation Time
20 ms
Minimum Sampling Time
10 ms
Number of Channels
1 CH
Input Voltage
Automatic adaptation to global 3-phase grids: 3×208V~3×440V ±10%, 50/60 Hz ±5%
Certificates
CE

Portable Battery Module Cycler