kapak foto for sliderr
Battery Testing
arka 2
Our Three-Level Testing Infrastructure
Cell Test Channel
Performance, durability, and safety testing of individual battery cells.
Module Test Channel
Thermal, electrical, and mechanical testing of battery modules composed of multiple cells.
Pack Test Channel
Comprehensive safety, charge–discharge, and performance testing of complete battery packs.
⚡Cell Test Channels – 7,860
(Planned: 14,000 CH)
(Planned: 14,000 CH)
🧩 Module Test Channels – 693
🔋 Pack Test Channels – 134
(Planned: 180 CH)
(Planned: 180 CH)
0
Milyon + CH
Cumulative Shipments
≤
0
ms
Minimum Acquisition Time
≤
0
ms
Fastest Current Rise
>
0
%
Regenerative Efficiency
0
% F.S.
Ultra-High Current and Voltage Accuracy
Battery Cell Cycle Test System
Model
JAT-JTFLCT-05300-E010 (CE)
Application Areas
Electric Vehicles
Charge Voltage
0V – 5V
Discharge Voltage
0V – 5V
Voltage Accuracy
0.02% F.S.
Current Accuracy
0.03% F.S.
Power Accuracy
0.05% F.S.
Automatic Current Ranges
50A / 100A / 200A / 300A
Current Range
0 – 300A (up to 3000A)
Current Rise Time
4ms
Switching Time
8ms
Simulation Time
20ms
Minimum Data Sampling Time
10ms
Number of Channels
16CH / 8CH
Input Voltage
400VAC ±10% (3 phase, 5 wire: A/B/C + N + PE)
Certification
CE
Portable Battery Cell Balancer
Model
JAT-JTCBR-360303PT / JAT-JTCBR-360505PT
Analog Battery Count
4~36 strings
Output Voltage
1500mV~4500mV
Output Voltage Accuracy
± (0.05% + 2) mV
Voltage Measurement Range
100mV~4800mV
Voltage Measurement Accuracy
± (0.05% + 2) mV
Charge Current Measurement Range
100mA~5000mA, supports pulse charging; automatically limits current to 3A after overheating
Output Current Accuracy
± (0.1% + 3) mA
Discharge Current Measurement Range
1mA~5000mA, supports pulse discharging; automatically limits current to 3A after overheating
Current Measurement Accuracy
± (0.1% + 3) mA
Charge Cut-off Current
50mA
Certification
CE
Battery Internal Resistance Tester
Model
JT-3563
Internal Resistance (IR) Range
3mΩ ~ 3000Ω
IR Accuracy
±0.3% reading ±30 digits / ±5 digits
Voltage Range
± (0.01mV ~ 300V)
Voltage Accuracy
±0.005% reading ±3 digits
Sampling Speed
17ms ~ 20ms
Data Storage Capacity
Over 30,000 test results
Dimensions / Weight
201W × 286D × 101H (mm), benchtop type, 4kg
Model
JT-3564
İç Direnç (IR) Aralığı
3mΩ ~ 3000Ω
IR Hassasiyeti
±0.3% okuma ±30 hane / ±5 hane
Gerilim Aralığı
± (0.01mV ~ 300V)
Gerilim Hassasiyeti
±0.005% okuma ±3 hane
Örnekleme Hızı
17ms ~ 20ms
Veri Depolama Kapasitesi
30.000’den fazla test sonucu
Boyut / Ağırlık
201W × 286D × 101H (mm), masa tipi 4kg
Model
JT-3565-H
Internal Resistance (IR) Range
3mΩ ~ 3000Ω
IR Accuracy
±0.3% reading ±30 digits / ±5 digits
Voltage Range
± (0.01mV ~ 2250V)
Voltage Accuracy
±0.01% reading ±3 digits / ±0.05% reading ±3 digits
Sampling Speed
17ms ~ 20ms
Data Storage Capacity
Over 30,000 test results
Dimensions / Weight
201W × 286D × 101H (mm), benchtop type, 5kg
Portable Battery Module Cycle Test System
Application Area
Research / Industry / After-Sales
Model
JAT-JTFLCT-300100PT-E002
Charge Voltage
0V ~ 300V
Discharge Voltage
0V ~ 300V
Voltage Accuracy
±0.02% F.S
Current Accuracy
±0.02% F.S
Current Range
0 ~ 100A
Power Accuracy
0.1% F.S
Maximum Power
20 kW
Current Rise Time
5 ms
Switching Time
10 ms
Simulation Time
20 ms
Minimum Sampling Time
10 ms
Number of Channels
1 CH
Input Voltage
Automatic adaptation to global 3-phase grids: 3×208V~3×440V ±10%, 50/60 Hz ±5%
Certifications
CE
Battery Module Cycle Test System 120V 125A
Model
JAT-JTEFLCT-120125-V001
Application Area
Electric Vehicles / Energy Storage
Charge Voltage
0 ~ 120V
Discharge Voltage
0 ~ 120V
Voltage Accuracy
±0.05% F.S
Current Accuracy
±0.05% F.S
Current Range
±125A
Power Accuracy
±0.1% F.S
Maximum Power / Channel
12 kW
Current Rise Time
5 ms
Switching Time
10 ms
Simulation Time
20 ms
Minimum Sampling Time
10 ms
Number of Channels
8 CH
Input Voltage
400VAC ±10%, 3-phase, 5-wire A/B/C+N+PE
Certification
CE
Battery Module Cycle Test System 100V 60A
Model
JAT-JTEM-10060-V006-US
Application Area
Small Power Batteries
Charge Voltage
3.3V ~ 100V
Discharge Voltage
6.5V ~ 100V
Voltage Accuracy
±0.05% F.S
Current Accuracy
±0.05% F.S
Current Range
0 ~ 60A
Power Accuracy
±0.1% F.S
Maximum Power / Channel
6 kW
Current Rise Time
5 ms
Switching Time
10 ms
Simulation Time
20 ms
Minimum Sampling Time
10 ms
Number of Channels
16 CH
Input Voltage
480VAC ±10%, 3-phase 5-wire (A/B/C+N+PE)
Certification
CE
Battery Pack Cycle Test System 600kW 1650V
Application Area
Research / Industry
Model
JAT-JTH-600165030002-V008
Usage Area
Research / Industry
Charge Voltage
70V ~ 1650V
Discharge Voltage
70V
Voltage Accuracy
±0.01% F.S
Current Accuracy
±0.03% F.S
Current Range
±300A
Power Accuracy
±0.1% F.S
Maximum Power / Channel
300 kW
Current Rise Time
4 ms
Switching Time
8 ms
Simulation Time
20 ms
Minimum Sampling Time
1 ms
Number of Channels
2 CH
Input Voltage
380VAC ±10%, 3-phase 5-wire (A/B/C+N+PE)
Certification
-
Application Area
Research / Industry
Model
JAT-JTH-600100060004-E004
Usage Area
Electric Vehicles / Energy Storage
Charge Voltage
1V ~ 1000V
Discharge Voltage
35V ~ 1000V
Voltage Accuracy
±0.01% F.S
Current Accuracy
±0.03% F.S
Current Range
0 ~ 600A
Power Accuracy
±0.05% F.S
Maximum Power / Channel
600 kW
Current Rise Time
4 ms (optional: 2 ms)
Switching Time
9 ms (optional: 4 ms)
Simulation Time
20 ms (optional: 10 ms)
Minimum Sampling Time
10 ms (optional: 1 ms)
Number of Channels
4 CH
Input Voltage
400VAC ±10%, 3-phase 5-wire (A/B/C+N+PE)
Certification
CE
Battery Pack Cycle Test System 1000V
Power Battery EOL Test System
Application Area
Research / Industry
Model
JAT-JTVPEOL-1T1-V003
Usage Area
Electric Vehicles
Equipotential Connection
1 set
AC Impedance
1 set
Insulation / Short Circuit Test
12 sets
Humidity / Temperature Test
1 set
LV Test
5 sets
BMS LV Supply
9 sets
Pull-up Resistor
(1K / 220Ω / 680Ω): 5 sets
Protocol Interface
CAN, NET, RS232, USB
PWM Square Wave Output
2 sets
Voltage: -12V ~ +12V
Frequency: 10Hz ~ 50kHz
Frequency Accuracy: ±3% R.D.
Duty Cycle: 5% ~ 95%
Communication Test
1 / 2 / 4 / 8 sets
Spare Relay
2 sets dry contact, 2 sets 10k resistor
Certification
CE
Application Area
Research / Industry
Model
JAT-JTVPEOL-1T2-V003
Usage Area
Electric Vehicles
Equipotential Connection
2 sets
AC Impedance
4 sets
Insulation / Short Circuit Test
24 sets
Humidity / Temperature Test
1 set
LV Test
10 sets
BMS LV Supply
18 sets
Pull-up Resistor
(1K / 220Ω / 680Ω): 10 sets
Protocol Interface
CAN, NET, RS232, USB
PWM Square Wave Output
4 sets
Voltage: -12V ~ +12V
Frequency: 10Hz ~ 50kHz
Frequency Accuracy: ±3% R.D.
Duty Cycle: 5% ~ 95%
Communication Test
2 / 4 / 8 / 16 sets
Spare Relay
4 sets dry contact, 4 sets 10k resistor
Certification
CE
Electrical Safety Analyzer
Application Area
Research / Maintenance / Verification / Industry
Model
JT-9301
ACW
5kVac / 100mA
DCW
6kVdc / 20mA
Insulation Resistance
6kVdc / 50GΩ
AC Resistance
-
DCGB
40Adc / 600mΩ (Optional)
Parallel Function
-
Multi-Channel Switching
8 CH HV scanning card
Operation & Interface
Android, 7-inch display
Standard: RS232 / RS485
Optional: USB, LAN, WiFi
Dimensions
426W × 132H × 420D (mm)
Application Area
Research / Maintenance / Verification / Industry
Model
JT-9303
ACW
5kVac / 100mA
DCW
6kVdc / 20mA
Insulation Resistance
6kVdc / 50GΩ
AC Resistance
64Aac / 600mΩ
DCGB
40Adc / 600mΩ (Optional)
Parallel Function
Grounding and insulation withstand test
Multi-Channel Switching
5 CH HV scanning card; 3 CH grounding card
Operation & Interface
Android, 7-inch display
Standard: RS232 / RS485
Optional: USB, LAN, WiFi
Dimensions
426W × 132H × 520D (mm)
Application Area
Research / Industry
Model
JTPD-18200030-V001
Source Mode
Voltage:
Range: 0 ~ 2000V
Accuracy: 0.02%R.D. + 0.02%F.S. (25°C ±5°C)
Resolution: 100mV
Current:
Range: -30A ~ +30A
Accuracy: 0.05%R.D. + 0.05%F.S.
Resolution: 1mA
Power:
Range: -18kW ~ +18kW
Accuracy: 0.5%R.D. + 0.5%F.S.
Resolution: 1W
Load Mode
Voltage:
Range: 10 ~ 2000V
Accuracy: 0.02%R.D. + 0.02%F.S. (25°C ±5°C)
Resolution: 100mV
Current:
Range: -30A ~ +30A
Accuracy: 0.05%R.D. + 0.05%F.S.
Resolution: 1mA
Power:
Range: -18kW ~ +18kW
Accuracy: 0.5%R.D. + 0.5%F.S.
Resolution: 1W
Temperature Coefficient
Voltage ≤50PPM/°C; Current ≤200PPM/°C
Voltage Ripple
Peak-to-Peak ≤2000mVpp; RMS ≤600mVpp
Sense Compensation
≤20V
AC Input
Voltage: 342V ~ 528V (3-phase, 4-wire)
Frequency: 47Hz ~ 63Hz
Maximum Efficiency
92%
Power Factor
99%
Interface
CAN, RS-232C, USB, Ethernet, Power Input, Test Interface, RS-485